Thermostat schedule
Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for all days
of the week.
Wake: Leave: Return: Sleep
Heating Schedule: 6:00 AM – 70°F: 8:00 AM – 62°F: 5:00 PM – 70°F: 10:00 PM – 62°F
Cooling Schedule: 6:00 AM – 75°F: 8:00 AM – 83°F: 5:00 PM – 75°F: 10:00 PM – 78°F
Note: Thermostat can be programmed on or off the subbase
Modify the Heating Schedule
1. Use the System button to select Heat
2. Press Menu
3. Use the button to select Schedule and press Next to enter the schedule
4. The time icons will flash – use or to set the time for the start of a period
5. Press Next – the set point icons will flash – use or to set the temperature for the current
period
6. Continue to press Next to advance through all periods (Wake, Leave, Return, Sleep) for all days of
the week.
Note: Press Back to return to the previous setting. Once all days of the week have been
programmed the thermostat will display End. Press Exit at any time to save changes and return
to home screen.
Modify the Cooling Schedule
1. Use the System button to select Cool
2. Repeat steps 2-6 from the heating schedule
SPECIFICATIONS
Electrical Rating:
Battery Power………………………………. mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire……………………………… 20 to 30 VAC, NEC Class II, 50/60 Hz
Terminal Load………………………………. 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Range…………………………….. 45° to 99° F (7° to 37° C)
Rated Differentials (@ 6°F/ Hr): ……… Fast Med Slow
Heat (Conventional Gas / Oil / Elect).. 0.5°F 0.75°F 1.9°F
Cool (Central Air)………………………….. 0.9°F 1.2°F 1.7°F
Heat Pump (Heat and Cool) …………… 0.9°F 1.2°F 1.7°F
Heat Pump Aux…………………………….. 0.5°F 0.75°F 1.9°F
Operating Ambient………………………… 32°F to +105°F (0° to +41°C)
Display Temperature Range…………… 32°F to +99°F (0 to 37°C)
Operating Humidity……………………….. 90% non-condensing maximum
Shipping Temperature Range…………. -20°F to + 150°F (-29° to +65°C)
Thermostat Dimensions…………………. 3-3/4” H x 6” W x 1-1/8” D
TROUBLESHOOTING
Symptom:
Possible Cause:
Corrective Action.
No Heat/No Cool/No Fan (common problem):
1. Blown fuse or tripped circuit breaker
2. Furnace power switch to OFF