Installation and operating instructions WILO Mather and Platt – VT pumps 44
Rotating part rubbing on stationary part Incorrect assembly, correct
the assembly
Bearing worn Check lubrication, shaft run out, alignment, replace if required
Wearing rings worn Replace
Casing gasket defective, permitting internal Replace
leakage
Shaft or shaft sleeves worn or scored at packing Replace
Packing improperly installed Use correct grade and size of packing
Type of packing incorrect for operating Use correct grade and size of packing
condition
Shaft running' out of center because of worn Rectify
bearings or misalignment
Rotor out of balance, causing vibration Balance the rotor
Gland too tight, resulting in no flow of liquid to Adjust gland. Ensure sealing water flow
lubricate packing
Cooling liquid not being provided to water- Provide
cooled stuffing boxes
Excessive clearance at bottom of stuffing box Check pumps assembly
between shaft and casing, causing packing to be
forced into the pump
Dirt or grit in sealing, liquid leading to scoring of Provide clean liquid for flushing
shaft or shaft sleeve
Excessive thrust caused by mechanical failure Check pump operation and assembly
inside pump or by failure of hydraulic balancing
device, if any (in case of multistage pump etc.)
Excessive grease or oil in antifriction bearing Attend
housing or lack of cooling, causing excessive
bearing temperature
Lack of lubrication Provide proper lubrication
Improper installation of antifriction bearings Rectify or replace bearing
(damage, incorrect assembly of stacked bearings,
use of unmatched bearings as a pair etc.)
Dirt in bearings Investigate the cause and clean bearing.
Rusting of bearings from water in housing Arrest water ingress
Excessive cooling of water- cooled bearing, Reduce cooling water flow
resulting in condensation of atmospheric
moisture in bearing housing