Malfunctions
16
Display
Meaning
Remedy
Blinks red
The temperature in the boiler or tank is
greater than 95°C.
Switch off the machine imme-
diately. The error code Err 2 or Err 3
appears.
Tell the Winterhalter service technician about
the fault message.
Blinks blue
Water level in the machine is too high.
The drain pump switches on and
drains until the normal level is
reached.
When the error occurs five times,
appears.
When you switch off the machine,
Err 21 is displayed.
Close the water stopcock so no more water
flows into the machine.
Tell the Winterhalter service technician about
the fault message.
Rack
conveyor
transport and
circulating
pump switch
off
Thermo protection switch of the built-in
geared motor or of an external drive
motor connected to the machine was
triggered.
Switch off the machine.
Err 11 is displayed.
Washing can continue as soon as the motor has
cooled off.
Tell the Winterhalter service technician about
the fault message.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Winterhalter STR series and is the answer not in the manual?

Winterhalter STR series Specifications

General IconGeneral
DimensionsVaries by model
Booster heater powerVaries by model
Total connected loadVaries by model
WeightVaries by model
ControlElectronic control
Featuresautomatic detergent dosing
Rack size500 x 500 mm
Power consumptionVaries by model
Dimensions (HxWxD)Varies by model
Drying systemResidual heat drying

Related product manuals