EasyManua.ls Logo

WKS i3 - Page 41

WKS i3
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
41 / 47
Max output current
13.7A 16A 18.2A 22.8A 27.3A
Nominal grid voltage &
frequency
220V,230V,240V, 44 55Hz or 54 66Hz
AC voltage range
180 276V (according to local authority requirements)
THD
<3%
Power factor
1default (+ / - 0.8 adjustable)
Inrush current
0.8A / 1us
Max output fault current
100A / 1us
System parameters
Max efficiency
Charge: 94.1% / discharge 94.3%
Standby losses
< 5W (PV SPS)
Topology
High frequency insolation(for bat)
Ingress protection ratings
IP 65
Safety protection
Anti-islanding, RCMU, ground fault monitoring
Communication
Wi-Fi/GPRS, RS485, SD,CAN2.0
Environmental data
Ambient temperature
range
-30 to +60(Derating above +45)
Relative humidity range
0% - 100% (no condensing)
Protective class
Class I
Max operating altitude
2000m
Current transformer
connection
Hard wired
General data
Noise
<25dB
Weight
20.5kg
Cooling
Natural convection
Dimensions (W*H*D)
566 x 394 x 173 mm
Display
LCD display
Warranty
5 years or more
EPS (Emergency Power Supply) data
EPS rated power
3000VA
EPS nominal voltage/freq
uency
230V, 50/60Hz
EPS rated current
13A
THD
<3%
Switch time
10mS default