2. Safety Notes
Before installation, please make sure you read & understand this manual. The WKS I inverter strictly comply with
safety rules of design and testing. During the installation, operation and maintenance, operators should abide by
local safety regulations. Improper operation may cause an electric shock or damage the equipment and properties.
2.1. Safety Notes
Electrical installation and maintenance must be carried out by competent electricians according to local
regulations.
WKS I inverter can only be installed by qualified electrician, and only those who have appropriate
accreditation, as required by local authority.
Do NOT put explosives or flammable materials, e.g. gasoline, kerosene, diesel, oil, wood slab, cotton, or rag
close to batteries or WKS I inverter.
Disconnect AC connection first, then disconnect battery & PV(PV1&PV2), then wait at least 5 minutes
(discharge capacitors) before maintenance to prevent electric shock.
WKS I inverter shall be disconnected completely (BAT, PV & AC) while being maintained.
WKS I inverter can be very hot during working. Switch off WKS I inverter & wait WKS I inverter to cool
down before maintenance.
Keep children away from batteries & WKS I inverter.
It’s NOT allowed to open the front cover of WKS I inverter. This will void the product warranty.
WKS I inverter damaged by improper installation/operation is NOT covered by the product warranty.
2
.2. Installation and Maintenance Notes
The battery has been charged more than 60% before being delivered and shall be prevented from short circuit
during transportation and installation.
WKS I inverter/batteries shall be placed in a well-ventilated place. Do not put the WKS I inverter/batteries in an
airtight or badly ventilated place or cabinet. This can be very harmful to system performance & service life.
Keep WKS I inverter/batteries away from direct sunshine. Don’t put WKS I inverter/batteries close to a
furnace or fire. The can lead battery to leak even explode.
The current capacity of DC power cables (from battery to inverter) should be at least 90A. Use short DC power
cables to avoid high voltage drop & power loss.
Use a multimeter to check the batter voltage & polarity before switching ON batteries. Make sure connections
are correct according to this manual.
Use a multimeter to check the PV voltage & polarity before switching ON PV isolator. Make sure connections
are correct according to this manual.
If you want to store the batteries without using them, they should be disconnected from WKS I inverter, and
be kept in a cool, dry, and ventilated environment.