6.4.2. Advanced setting:
2.Advanced Setting Input Password 0715
Up”
“Down
1.Battery Parameter
2.Clear Energy Data
3.Clear Events
4.Country
5.Anti Reflux
6.IV Curve Scan
7.Battery Active
8.DRMs0 Control
9.Safety Param.
Select “2. Advanced Setting and press “OK, “input password” is shown. Input the password ”0715”, press “Up” or
“Down” to change the 1
st
digit, press OK” to switch to next digit, when “0715” is shown on the screen, press “OK”
to enter “2. Advanced Setting interface.
If “Incorrect, Try Again! is shown on the screen, press “Back” and input the password again.
1. Battery Parameter
1.Battery Parameter
1)Battery Type
7)Max Discharge (A)
2)*Battery Capacity 8)*Low (V) Protection
3)Discharge Depth 9)*Min Discharge (V)
4)Max Charge (A)
10)*Empty Discharged (V)
5)*Over (V) Protection 11)*Full Charged (V)
6)*Max Charge (V) 12)Save
Note: 2)*, 5)*, 6)*, 8)*, 9)*, 10)* and 11)* settings are only for DEFAULT battery type.
1) Battery Type (refer to Set battery type)
Select “1. Battery Type” and press “OK. Press “up” or “down” to select the battery type. Press “OK”.
2) *Battery Capacity (only for DEFAULT battery type)
Select 2. Battery Capacity” and press “OK”. Press “up” or down” to change the 1
st
digit, press “ok” to switch to next
digit. Input the value of battery capacity. Press “OK”.
“Up”