Care
46
> Unscrew the black cap (4h) from the air intake pipe.
> Mix one measuring cap of WMF milk system cleaner with 200 ml water in a container.
> Place all parts of the milk system in the cleaning solution for minimum 5 hours or overnight.
> Finally, rinse all the parts thoroughly under running water.
> Clean the opening of the beverage spouts with the brushes provided.
> Assemble the milk foamer again in the following manner (see illustration on page 45 on the right hand
side):
- Push the top section into the lower section (4f), so that it clicks in place.
- Screw the air inlet pipe (4g) in place.
- Screw the black cap (4h) onto the air inlet pipe.
- Insert the milk hose (4c) into the milk foamer again.
> Insert the milk foamer into the All-in-One spout from below.
> Push the All-in-One spout downwards.
> Insert the milk hose into the guide.