Display messages and malfunctions
63
5.2 Problems without error display
Problem Rectifi cation measure
No milk foam - / milk
output, although there is
milk in the container
> Check whether the milk hose is kinked or squashed.
> Re-fi t the milk hose again.
> Clean the All-in-one spout (see Chapter 4.3.1).
Steam nozzle correctly assembled?
> Fit the steam nozzle as described in Chapter 4.3.2.
No milk foam
only hot milk
> Check that the outlet is in the uppermost position. Pull the outlet
downwards.
> Carry out a milk system rinsing operation.
Does the problem persist?
> Clean the milk system.
> Clean the steam nozzle (see Chapter 4.3.2).
Milk or milk foam
too cold
> Ensure that the correct milk nozzle is attached to the milk hose (white
for refrigerated milk, brown for unrefrigerated milk).