EasyManua.ls Logo

Wolf BM-2 - Default Settings Overview; Heating Appliance Settings

Wolf BM-2
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3064202_201602 23
Default settings overview
16 Default settings overview
A list of all default settings can be found below:
Parameter Setting range Factory setting Chapter
Heating appliance – DHW mode ECO / Comfort ECO 16.1.1
Heating circuit 16.2
Mixer 1 - 7 16.2
Language Deutsch 16.3
Time 00:00 - 24:00 h 16.4
Date 01/01/2011 - 31/12/2099 16.5
Winter/summertime Auto/manual Auto 16.6
Min. backlighting 5 % - 15 % 10 % 16.7
Screensaver ON / OFF OFF 16.8
Key lock ON / OFF OFF 16.9
User interface
Extended /
Simplied
Extended 16.10
The following is a list of all default settings for
heating circuit and mixer circuit 1-7
Economy factor in economy mode 0 - 10 4 16.2.1
Winter/summer changeover 0 °C - 40 °C 20 °C 16.2.2
ECO / ABS -10 °C - 40 °C 10 °C 16.2.3
Day temperature (BM-2 in wall mounting
base and room inuence enabled)
5 °C - 30 °C 20 °C 16.2.4
Room inuence (BM-2 in wall mounting
base)
ON / OFF OFF 16.2.5
16.1 Heating appliance
16.1.1 DHW operating mode
Setting range: ECO / Comfort
Factory setting: ECO
The DHW operating mode function only applies to combi boilers. The Comfort setting activates a DHW quick start
and keeps the heating appliance at the right temperature to ensure rapid DHW heating. In the ECO setting, the
heating appliance is not brought up to temperature until the tap is opened.
14:12 20.01.13
Heating appliance
Heating circuit
Mixer 1
Language
English
Default settings
14:12 20.01.13
DHW operating mode
Value: Comfort
Heating appliance
14:12 20.01.13
Main menu
Display
Default settings
Time programs
Contractor level
Entry

Table of Contents