2 Remove the top plate from the unit.
Remove the Temperature Sensor 300C
1 Disconnect the temperature sensor 300C electrical
connector from the unit relay board.
2 Use a T-15 Torx bit to remove the screw from the
temperature sensor 300C.
3 Remove the temperature sensor 300C from the top exhaust
duct.
TEMPERATURE SENSOR 300C INSTALLATION
Install the Temperature Sensor 300C
1 Insert the temperature sensor 300C into the top exhaust
duct.
2 Use a T-15 Torx bit to install the screw into the temperature
sensor 300C.
3 Connect the temperature sensor 300C electrical connector
to the unit relay board.
Install the Top Plate
1 Place the top plate on the unit.
2 Use a T-20 Torx bit to install the screws into the top plate.
STEPPER MOTOR REMOVAL
To remove the stepper motor, first remove the top plate.
Remove the Top Plate
1 Use a T-20 Torx bit to remove the screws from the top and
back of the unit.
2 Remove the top plate from the unit.
Remove the Stepper Motor
1 Disconnect the electrical connector from the stepper motor.
2 Use a flat-blade screwdriver to pry the tabs up on the
stepper motor retainer, while pulling the stepper motor
toward the front of the unit.
3 Remove the stepper motor from the unit.