Error Code Error Possible Cause Test/Action
2 Replace the control board if the error continues.
E107 Operating system:
NVRAM-FLASH
structure data error.
Moisture on control
board.
1 Inspect the control board for moisture.
2 Replace the control board if the error continues.
E108 Operating system:
NVRAM-FLASH
checksum data error.
Moisture on control
board.
1 Inspect the control board for moisture.
2 Replace the control board if the error continues.
E109 Operating system:
NVRAM fatal read
error.
Moisture on control
board.
1 Inspect the control board for moisture.
2 Replace the control board if the error continues.
E110 Operating system:
CORE maximum
SYNCH_DURATION.
Moisture on control
board.
1 Inspect the control board for moisture.
2 Replace the control board if the error continues.
E111/F5 Operating system:
Error in control board
checksum.
Replace the control board.
E112/F5 Operating system:
Error in relay board
checksum.
Replace the control board and relay board.
E113 Operating system:
Kernel stack overflow
in the control board.
Replace the control board.
E114 Operating system:
Kernel stack error in
the relay board.
Replace the relay board.
E115/F29 Door lock not
initialized.
1 Check the wiring.
2 Replace the relay board.
E116 Door lock switch.
1 Check the wiring.
2 Replace the relay board.
E117/F29 Short in the motor
circuit for the door
lock.
1 Check the wiring.
2 Replace the relay board.
E118/F29 Open circuit in the
motor for the door
lock.
1 Check the wiring.
2 Replace the relay board.
E119/F5 External firmware error. Replace the control board.
E120/F5 SOUNDLIBRARY error. Replace the control board.
E121/F5 PICTURELIBRARY
error.
Replace the control board.
E122/F5 TEXTLIBRARY error. Replace the control board.
E123/F5 FONTLIBRARY error. Replace the control board.
E124/F5 MODELCONFIGLIBRA
RY error.
Replace the control board.
E125/F5 PRESENTATIONLIBRA
RY error.
Replace the control board.
E131/F5 FACTORYSETTINGLIB
RARY error.
Replace the control board.
E132/F5 EASYCOOK data
invalid.
Replace the control board.
E133/F32 Calibration value error
in the water level
measurement.
Replace the control board.
E136/F16 Thermostat 160C
defective.
Replace the thermostat 160C.
E137/F16 Actuator defective. High resistance to
element, bake element,
1 Check all the element wiring.
CSO (SWS #13543126)
Troubleshooting
Troubleshooting Guide
service.subzero.com
827703 REV B.1
91