Flue gas routing options
Maximum length
1)
[m]
up to
28 kW
up to
35 kW
B23P
Flue in a shaft and combustion air
directly via boiler (open ue)
DN60
DN80
11
50
7
50
B33P
Flue in a shaft with horizontal,
concentric connecting pipe (open ue)
DN60
DN80
9
50
5
50
B33P
Connection to moisture-resistant chimney
with horizontal concentric
connecting pipe (open ue)
Calculation to EN 13384
(room sealed balanced
ue manufacturer)
C13x
Horizontal roof outlet through pitched roof
(balanced ue – on-site dormer)
DN60/100
DN80/125
5
10
3
10
C33x
Vertical concentric roof outlet through pitched or at roof,
vertical concentric balanced ue system for installation
in a shaft (room sealed)
DN60/100
DN80/125
DN110/160
6
18
19
4
29
48
C43x
Connection to moisture-resistant room sealed balanced ue chimney,
maximum pipe length from centre of boiler bend to
connection 2 m (room sealed)
Calculation to EN 13384
(room sealed balanced
ue manufacturer)
C53
Connection to ue in a shaft and ventilation air supply through external wall
(room sealed), 3 m ventilation air duct incl.
DN80/80 50 50
C53x
Connection to ue on external wall, combustion air intake via external wall
(room sealed)
DN60/100
DN80/125
9
50
5
50
C83x
Connection to ue in a shaft and ventilation air through external wall
(room sealed)
DN80/125 50 50
C83x
Concentric connection to moisture-resistant ue
gas chimney and combustion air
through external wall (room sealed)
Calculation to EN 13384
(room sealed balanced
ue manufacturer)
C93x
Flue for installation in a shaft,
connecting pipe DN60/100, vertical DN60
rigid 8 5
C93x
Flue for installation in a shaft, vertical DN80
connecting pipe DN60/100
connecting pipe DN80/125
connecting pipe DN80/125
rigid
rigid
exible
14
15
14
27
39
37
1)
Themaximumlengthcorrespondstothetotallengthfromtheappliancetotheueterminal.
Foravailableliftingpressuresofgasblowers,seespecication.
Note: Systems C33x and C83x are also suitable for
installation in garages.
Where necessary, adapt the installation examples to the
relevant building regulations and requirements in your
country/region. Any questions relating to the installation,
particularly regarding the provision of inspection
components and ventilation apertures (ventilation generally
required above 50 kW output) should be raised with your
local ue gas inspector prior to installation.
Thespeciedlengthsrefertoconcentricbalanced
uesandstandardues,andapplytooriginalWolf
components only.
BalanceduesystemsDN60/100andDN80/125
arecertiedassingleunitstogetherwithWolfgas
condensing boilers.
The following balanced ues or standard ues with
CE-0036-CPD-9169003 certication may be used:
- Flue pipe DN80
- Concentric balanced ue DN60/100 and DN80/125
- Flue pipe DN110
-
Concentric balanced ue (on external walls) DN80/125
- Flexible ue pipe DN83
Wolf accessories are supplied with the relevant necessary
identication labels.
Please also observe the installation information supplied
with the accessories.
31.Technicalinformation,balancedue