APPLIANCE INFORMATION
6 720 806 548 (2013/02)6
2.2 TECHNICAL DATA
NATURAL GAS L.P.G
DESCRIPTION UNITS 30CDi 40CDi 30CDi 40CDi
Heating
Max. rated heat input kW 30.9 42.0 30.9 42.0
Max. rated heat output net 40/30°C kW 32.1 43.7 32.1 43.7
Max. rated heat output net 50/30°C kW 31.8 43.3 31.8 43.3
Max. rated heat output net 80/60°C kW 30.0 40.8 30.0 40.8
Min. rated heat output net 40/30°C kW 8.6 10.6 12.4 15.7
Min. rated heat output net 50/30°C kW 8.6 10.5 12.3 15.5
Min. rated heat output net 80/60°C kW 7.7 9.4 11.0 13.9
Min. rated heat input net kW 8.0 9.8 11.5 14.5
Max. flow temperature °C nom.90 nom.90 nom.90 nom.90
Max. permissible operating pressure bar 3.0 3.0 3.0 3.0
Gas flow rate - Max. 10 minutes from lighting
Natural Gas G20 m3/h 3.2 4.4 --
Propane Gas (LPG) kg/h --2.4 3.3
Flue
Flue Gas Temp. 80/60°C, rated min. load °C 76/58 87/58 76/58 87/58
Flue Gas Temp. 40/30°C, rated min. load °C 55/33 58/35 55/33 58/35
CO2 level at max. rated heat output % 9.6 9.7 11.5 11.5
CO2 level at min. rated heat output % 9.0 9.1 10.5 10.5
NOx - class 5555
Condensate
Max. condensation rate I/h 2.7 3.7 2.7 3.7
pH value, approx. 4.8 4.8 4.8 4.8
Electrical
Electrical power supply voltage AC...V 230 230 230 230
Frequency Hz 50 50 50 50
Max. power consumption W approx.70 approx.100 approx.70 approx.100
General Data
SEDBUK band AAAA
Appliance protection rating IP X4D X4D X4D X4D
Permissible ambient temperatures °C 0-50 0-50 0-50 0-50
Nominal capacity of appliance I 3.5 3.5 3.5 3.5
Noise output level dB(A) 43 47 43 47
Total boiler weight (lift weight) kg 39.5 39.5 39.5 39.5
Packaged boiler weight kg 48 48 48 48
SEDBUK 2005 % 90.3 90.2 92.3 92.0
SEDBUK 2009 % 89. 89.1 90.5 90.2
Table 3 Technical data