APPLIANCE
INFORMATION
INSTALLATION & SERVICING INSTRUCTIONS
4
TECHNICAL DATA
TECHNICAL DATA
8 716 115 216b (09.2008)
DESCRIPTION UNITS Natural Gas L.P.G
FS 30CDi FS 42CDi FS 30CDi FS 42CDi
Central Heating
Max. rated heat output net 40/30°C kW 32.1 43.7 32.1 43.7
Max. rated heat output net 50/30°C kW 31.8 43.3 31.8 43.3
Max. rated heat output net 80/60°C kW 30 40.8 30 40.8
Max. rated heat input net kW 30.9 42 30.9 42
Min. rated heat output net 40/30°C kW 8.6 10.8 11.6 13.5
Min. rated heat output net 50/30°C kW 8.6 10.7 11.4 13.4
Min. rated heat output net 80/60°C kW 7.7 9.6 10.5 12.0
Min. rated heat input net kW 8 10 10.8 12.5
Max. flow temperature °C 88 88 88 88
Max. permissible operating pressure bar 2.65 2.65 2.65 2.65
Gas flow rate - Max. 10 minutes from lighting
Natural Gas G20 m
3
/h 3.27 4.4 - -
Propane Gas (LPG) kg/h - - 2.3 3.3
Gas supply pressure
Natural Gas G20 mb 20 20
LPG (Propane) Gas G31 mb - - 37 37
Flue
Flue Gas Temp. 80/60°C, rated min. load °C 67/55 67/55 67/55 67/55
Flue Gas Temp. 40/30°C, rated min. load °C 43/32 43/32 43/32 43/32
CO
2
level at max. rated heat output % 9.4 9.4 10.8 10.8
CO
2
level at min. rated heat output % 8.6 9.0 10.4 10.4
NO
x
- classification class 5 5 5 5
Condensate
Max. condensation rate l/h 2.7 3.7 2.7 3.7
pH value, approx. 4.8 4.8 4.8 4.8
Electrical
Electrical power supply voltage AC...V 230 230 230 230
Frequency Hz 50 50 50 50
Max. power consumption (without pump) W 60 80 60 80
General Data
SEDBUK (Band A) % 90.5 90.3 91.9 91.1
Appliance protection rating IP x4D x4D x4D x4D
Permissable ambient temperatures °C 0 - 50 0 - 50 0 - 50 0 - 50
Nominal capacity of appliance Itr 3.75 3.75 3.75 3.75
Noise output level (at maximum CH output) dB(A) 37 37 37 37
Weight (excluding packaging) kg 55.1 55.1 55.1 55.1

Other manuals for Worcester Greenstar FS 42CDi Regular

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Worcester Greenstar FS 42CDi Regular and is the answer not in the manual?

Worcester Greenstar FS 42CDi Regular Specifications

General IconGeneral
BrandWorcester
ModelGreenstar FS 42CDi Regular
CategoryBoiler
LanguageEnglish

Related product manuals