Default Settings
975-0799-01-01 9
Feature Description
15
20 A supplementary protector with reset button
provides overload protection for the Freedom XC
PRO GFCI Kit (PN: 808-9817) (sold separately)
option.
Press to recover from an overload condition. In a
hard wired installation, the supplementary protector
does not protect output wiring.
16
Ventilation grille (openings) must not be obstructed
for the proper operation of the cooling fan and
inverter/charger. When the inverter/charger is
mounted, the ventilation grille must not point up or
down.
Cooling fans turn on when the internal temperature
reaches a set point temperature.
17
Mounting flanges on both sides allow you to mount
the inverter/charger permanently on deck or on a
wall.
WARNING
ELECTRICAL SHOCK HAZARD
l
Use a torque screwdriver to tighten the bolt on the DC ground
lug to a torque of 23 in-lb (2.6 N-m) of force.
l
Apply an anti-corrosion compound to the copper wire prior to
connecting to the DC ground lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.