EasyManua.ls Logo

Xantrex Freedom XC PRO Series

Xantrex Freedom XC PRO Series
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating During Transition Between Grid Mode and Battery Mode
975-0799-01-01 65
Overload Conditions
There are two kinds of overload conditionsan overload warning
and an overload shutdown.
Overload
Warning
When the Freedom XC PRO’s AC load is approximately
100W below the overload shutdown limit of rated watts,
the audible alarm beeps once and the LCD screen
shows a error code E06.
Overload
Shutdown
When the Freedom XC PRO’s AC load increases to near
~2100W (Freedom XC PRO 2000) and ~3200W
(Freedom XC PRO 3000), the audible alarm beeps
every five seconds for one minute and the LCD screen
shows a error code E03. The Status LED turns solid
RED.
High Surge Loads
Some induction motors used in freezers, pumps, and other motor-
operated equipment require high surge currents to start. The
Freedom XC PRO may not be able to start some of these motors
even though their rated steady state current draw is within the
inverter/charger’s limits. The unit will shut down and indicate an
overload shutdown.
Over-temperature Conditions
During inverter operation, when the Freedom XC PRO’s internal
temperature starts to approach its preset shutdown limit, the
display will show error code E07. If the over-temperature condition
persists, the display will show error code E04. The Status LED
turns solid RED and the inverter/charger will shut down to prevent
damage to the inverter/charger and protect the battery from being
over-discharged.

Table of Contents

Related product manuals