Installation
975-0171-01-01 23
7. Using a 1/4" blade slot screwdriver, loosen the terminal screws on the
terminals. Do not remove the screws.
8. Connect the line and neutral wires to the input terminals (labeled AC Input on
the terminal block, Figure 5 on page 22). Connect Line 1 to L1, Neutral to N,
Line 2 to L2.
9. Tighten the terminal screws. Leave some slack wire inside the wiring box.
10. Connect the ground wires to a free position on the ground bus, Figure 5 on
page 22. If solid ground wire is being used, the wire can be connected directly
under the screw heads. If stranded ground wire is being used, ring terminals
must also be used.
11. Secure the strain-relief clamp on the AC input cable jacket.