Installation
975-0171-01-01 35
Step 7: Performing Checks Prior to Initial Start-Up
Before testing your installation, ensure these conditions are met:
p Chassis and AC grounds are properly installed.
p AC input connections and AC output connections are wired correctly on the
terminal block and not reversed.
p Positive (+) battery cable is connected to the positive (+) battery terminal
through the DC fuse and disconnect switch or DC circuit breaker.
p Negative (–) battery cable is connected to the negative (–) battery terminal.
p Battery voltage is within the proper range for this unit
(10.3–15.3 volts DC).
p DC disconnect switch or breaker is turned off.
p AC input and output breakers are turned off.
p All connections are tight.