EasyManua.ls Logo

Xantrex RS3000

Xantrex RS3000
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Battery Charging Reference
975-0170-01-01 B–5
Two-Stage Charging
If the two-stage charge is enabled, the charger finishes the absorption
charge but does not go to float mode because some battery manufacturers
advise against floating their batteries. The RS3000 goes into a monitoring
mode instead where the charger monitors the batteries but does not float
them.
A new two-stage charge cycle will be initiated under the same conditions
as for three-stage charging.
Charge Algorithm Graph
Charge Algorithm Definitions
Table B-1
Battery Defaults
Figure B-1
Three-Stage Charging Profile
Voltage Flooded (or wet) Gel AGM
V
A
Absorption Voltage (VDC) 14.4 14.4 14.3
V
G
Gassing Voltage (VDC) 13.5 13.8 13.45
V
F1
Float Voltage (VDC) 13.5 13.8 13.45
V
F2
Float Exit Voltage (VDC) 12.5 12.5 12.5
I
H
I
B
V
F2
V
F1
V
G
V
A
Float
Time
T
CV
T
A
T
F
Bulk Absorption

Table of Contents

Other manuals for Xantrex RS3000

Related product manuals