Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 161
Wait-to-Continue Command
The Wait-to-Continue command prevents the power supply from executing any
further commands or queries until the no-operation-pending flag is TRUE.
Command: *WAI
Operation Status Register Commands
Query Operation Status Register Event
SCPI command: STATus[<channel>]:OPERation[:EVENt]?
Query Operation Status Register Condition
SCPI command: STATus[<channel>]:OPERation:CONDition?
Enable Operation Status Register
SCPI command:
STATus[<channel>]:OPERation:ENABle <status-enable>
Query Format:
STATus[<channel>]:OPERation:ENABle?
Set Operation Status Positive Transition Filter
SCPI command:
STATus[<channel>]:OPERation:PTRansition <status-enable>
Query Format:
STATus[<channel>]:OPERation:PTRansition?
Set Operation Status Negative Transition Filter
SCPI command:
STATus[<channel>]:OPERation:NTRansition <status-enable>
Query Format:
STATus[<channel>]:OPERation:NTRansition?
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com