Remote Operation
SCPI Commands for Digital Interfaces
168 Operating Manual for XDC Series Power Supply
Voltage Sub-Register Commands
Query Voltage Sub-Register Event
SCPI command:
STATus[<channel>]:QUEStionable:VOLTage[:EVENt]?
Query Voltage Sub-Register Condition
SCPI command:
STATus[<channel>]:QUEStionable:VOLTage:CONDition?
Enable Voltage Sub-Register
SCPI command:
STATus[<channel>]:QUEStionable:VOLTage:ENABle
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:VOLTage:ENABle?
Set Voltage Positive Transition Filter
SCPI command:
STATus[<channel>]:QUEStionable:VOLTage:PTRansition
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:VOLTage:PTRansition?
Set Voltage Negative Transition Filter
SCPI command:
STATus[<channel>]:QUEStionable:VOLTage:NTRansition
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:VOLTage:NTRansition?