Remote Operation
SCPI Commands for Digital Interfaces
Release 3.0 171
Temperature Sub-Register Commands
Query Questionable Temperature Sub-Register Event
Temperature Event Sub-Register is read and then cleared.
SCPI command:
STATus[<channel>]:QUEStionable:TEMPerature[:EVENt]?
Query Questionable Temperature Sub-Register Condition
SCPI command:
STATus[<channel>]:QUEStionable:TEMPerature:CONDition?
Enable Temperature Sub-Register
SCPI command:
STATus[<channel>]:QUEStionable:TEMPerature:ENABle
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:TEMPerature:ENABle?
Set Temperature Positive Transition Filter
SCPI command:
STATus[<channel>]:QUEStionable:TEMPerature:PTRansition
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:TEMPerature:PTRansition?
Set Temperature Negative Transition Filter
SCPI command:
STATus[<channel>]:QUEStionable:TEMPerature:NTRansition
<status-enable>
Query Format:
STATus[<channel>]:QUEStionable:TEMPerature:NTRansition?