A.6 Sensor List
Sensor Description Component
Inlet Temp Air inlet temperature Right mounting ear
Outlet Temp Air outlet temperature BMC card
PCH Temp PCH bridge temperature Mainboard
PCH Status PCH chip fault diagnosis
health status
Mainboard
1711 Core Temp Core temperature of the
BMC management chip
BMC card
SSD Max Temp Maximum SSD
temperature (reported by
BMA)
SSD
CPUN Core Temp CPU core temperature CPUN
N indicates the CPU
number. The value is 1 or
2.
CPUN DTS Difference between the
real-time CPU
temperature and the CPU
core temperature
threshold
CPUN
N indicates the CPU
number. The value is 1 or
2.
CpuN Margin Difference between the
real-time CPU
temperature and the CPU
Tcontrol threshold
CPUN
N indicates the CPU
number. The value is 1 or
2.
CPUN MEM Temp CPU memory module
temperature
Memory module
corresponding to CPU N
N indicates the CPU
number. The value is 1 or
2.
CPUN 12V 12 V voltage supplied by
the mainboard to the CPU
Mainboard
N indicates the CPU
number. The value is 1 or
2.
CPUN Status CPU status detection CPUN
N indicates the CPU
number. The value is 1 or
2.
FusionServer 2288H V7 Server
Technical White Paper A Appendix
Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd. 150