Activity
Indicator
(Green)
Fault Indicator
(Red/Blue)
Description
Blinking at 4 Hz Off Data is being read from or written to
the NVMe drive.
Steady on/
blinking
Blinking blue at 4
Hz
The NVMe drive is being located.
Off Blinking red at
0.5 Hz
The NVMe drive has completed the
hot swap process and is removable.
Off Blinking red at 2
Hz
The NVMe drive is being hot-
swapped.
Steady on/Off Red steady on The NVMe drive is faulty.
 
5.5.3 RAID Controller Card
The RAID controller card supports RAID configuration, RAID level migration, and
drive roaming.
● For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the Compatibility Checker.
● For details about the RAID controller card, see the V7 Server RAID Controller
Card User Guide.
5.6 Network
5.6.1 OCP 3.0 NIC
OCP 3.0 NICs provide network expansion capabilities.
● The FlexIO slot supports an OCP 3.0 NIC, which can be configured as required.
● For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the Compatibility Checker.
● For details about OCP 3.0 NICs, see the documents of each OCP 3.0 NIC.
5.7 I/O Expansion
5.7.1 PCIe Cards
PCIe cards provide ease of expandability and connection.
● The server with a drive module or a PCIe riser module on the rear panel
supports up to eight standard PCIe expansion slots.
FusionServer 2288H V7 Server
Technical White Paper 5 Hardware Description
Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd. 78