EasyManua.ls Logo

xFusion Digital Technologies FusionServer 2288H V7 - 12 X 3.5 Drive Pass-Through Configurations

xFusion Digital Technologies FusionServer 2288H V7
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Drive No. Drive Number
Displayed on the iBMC
WebUI
Drive Number
Identified by the RAID
Controller Card
5 5
5
Note
6 6
6
Note
7 7
7
Note
8 8 -
9 9 -
10 10 -
11 11 -
Note: If the slot is configured with a SAS/SATA drive, the RAID controller card
can manage the drive and allocate a number to the drive.
5.5.1.3 12 x 3.5" Drive Pass-Through Configurations
Drive Configurations
Table 5-17 Drive configurations
Configuratio
n
Front Drive Rear Drive Built-in Drive Drive
Management
Mode
12 x 3.5" drive
pass-through
configuration
1
Front drive:
12 x 3.5"
Slots 0
to 11
support
only
SATA
drives.
I/O module
1: 2 x
2.5"
a
/2 x
3.5"
Slots 40
to 41
support
only
SATA
drives.
I/O module
3: 4 x 2.5"
Slots 44
to 47
support
only
NVMe
drives
b
.
-
SATA drive:
PCH pass-
through
NVMe
drive: CPU
pass-
through
FusionServer 2288H V7 Server
Technical White Paper 5 Hardware Description
Issue 02 (2023-05-25) Copyright © xFusion Digital Technologies Co., Ltd. 43

Table of Contents

Related product manuals