145
Main
type
Sub
type
Code
Description
Reasons
Solutions
31
5
E-315
When the
motor code is
read
automatically,
the motor
parameter is 0
Read the motor code
is 0
On the premise that the driver and
motor are matched and can be used
together, read the alarm shielding
position of motor parameters through
P0-53, and set the motor code
correctly
6
E-316
Auto-read
code error
The auto read motor
code is inconsistent
with the motor code
set in P0-33
Check U3-00 and motor label.
If the two values are the same,
change P0-33 motor code or set P0-33
to 0 to read motor code automatically;
If the two values are different,
contact the manufacturer for technical
support
85
2
E-852
Interruption of
data
interaction
with
CANopen
master station
Communication
interruption between
master and slave
station
Check whether the CAN network
wiring is disconnected or damaged;
Check whether the CANopen master
station is powered down;
After ensuring that there is no
problem with the wiring, first power off
and restart CANopen slave station, and
then power off and restart CANopen
master station.