V5 series inverter
48
10. Swing frequency and measurement functions parameters (Group 9)
Group P9: Swing frequency and measurement function parameters
Parameters Name Range
Minmum unit Default
setting
Change
P9.00 Swing frequency selection 0: Disabled
1: Enabled
1 0 ×
P9.01 Swing frequency mode 00~11
Lowest bit: input mode
0: Auto input mode
1: Manual input mode
Ten bit: Amplitude control
0: Variable amplitude
1: Fixed amplitude
1 00
×
P9.02 Preset swing frequecncy 0.00~500.00Hz 0.01Hz 0.00Hz ○
P9.03
Waiting time of preset swing
frequency
0.0~3600.0s 0.1s 0.0s ○
P9.04 Swing frequency amplitude 0.0~50.0% 0.1% 0.0% ○
P9.05 Jitter frequency 0.0~50.0%
(with reference to P9.04)
0.1% 0.0% ○
P9.06 Swing frequency cycle 0.1~999.9s 0.1s 10.0s ○
P9.07 Rising time of trangle wave 0.0~98.0%
(with)
0.1% 50.0% ○
P9.08 Setting length 0.000 ~ 65.535(km) 0.001km 0.000km ○
P9.09 Actual length 0.0~65.535km
(Saving at power off )
0.001km 0.000km ○
P9.10 Rates of length 0.001~30.000 0.001 1.000 ○
P9.11 Correction coefficient of
length
0.001~1.000 0.001 1.000 ○
P9.12 Perimeter of shaft 0.01~100.00cm 0.01cm 10.00cm ○
P9.13 Number of pulses per revolu-
tion
1~9999 1 1 ○
11. Vector control parameters
(Group PA)
Group PA: Vector Control Parameters
Parameter Name Range
Minmum
unit
Factory setting
Change
PA.00 Motor auto-tune 0: No tune
1: auto tune
1 0 ×
PA.01 Rated voltage of motor 0~400V 1 Dependent on in-
verter’s model
×
PA.02 Rated current of motor 0.01~500.00A 0.01A Dependent on in-
verter’s model
×
PA.03 Rated frequency of motor 1~99Hz 1Hz Dependent on in-
verter’s model
×
PA.04 Rated speed of motor 1~9999 r/min 1r/min Dependent on in-
verter’s model
×