TX91 3.8- 10kVA Users Manual
Page 5
Uninterrupble Power Supply
• Connect your UPS power module’s grounding terminal to a grounding electrode conductor.
• The UPS is connected to a DC energy source (baery). The output terminals may be live when the UPS
is not connected to an AC supply.
• Warning labels should be placed on all primary power switches installed in places away from the
device to alert the electrical maintenance personnel of the presence of a UPS in the circuit. The label will
bear the following or an equivalent text:
Before working on this circuit
Isolate Uninterrupble Power Supply (UPS)
Then check for Hazardous Voltage between
all terminals including the protected ground
Risk of Voltage Backfeed
1.5 Maintenance
• Even aer the UPS is disconnected from the mains, the components inside are sll connected to the
baery packs which may be potenally dangerous.
• Before carrying out any kind of service or maintenance, disconnect the baeries and verify that no
current is present and no hazardous voltage exists in the terminals of high capability capacitor such as
BUS-capacitors.
• Verify that no between the baery terminals and the ground is present before maintenance or repair.
In this product, the baery circuit is not isolated from the input voltage. Hazardous voltages may occur
between the baery terminals and the ground.
• Baeries may cause electric shock and have a high short-circuit current. Please remove all wristwatch-
es, rings and other metal personal objects before maintenance or repair, and only use tools with insu-
lated grips and handles for maintaining or repairing.
• When replacing the baeries, install the same number and same type of baeries.
• Do not aempt to dispose of baeries by burning them. This could cause baery explosion. The baer-
ies must be rightly deposed according to local regulaon.
• Do not open or destroy baeries. Escaping electrolyte can cause injury to the skin and eyes. It may be
toxic.
• Please replace the fuse only with the same type and amperage in order to avoid re hazards.
• Do not disassemble the UPS system.
TX91 3.8 -10kVA & TX91L 3.8 10kVA Users Manual Uninterrupble Power Supply
Xtreme Power Conversion Corporaon Page 3
• When replacing baeries, it is necessary to replace ALL baeries with the same quanty, type & capac-
ity.
• Do not plug or unplug the baery connector if UPS is working in baery mode.
• This unit is not designed for outdoor use.
1.6 Operaon
• Do not disconnect the ground conductor cable on the UPS or the building wiring terminals in any me
since this would cancel the protecve ground of the UPS system and of all connected loads.
• The UPS system features its own, internal current source (baeries). The UPS output receptacles or
output terminal blocks may be electrically live even if the UPS system is not connected to the building
wiring system.
• In order to fully disconnect the UPS system, rst press the “OFF” buon and then disconnect the
mains.
• Ensure that no liquid or other foreign objects can enter into the UPS system.
• The UPS can be operated by any individuals with no previous experience.