12 Genyo plus, Additional Installation, Operation and Maintenance Instructions
3.4.2 LEDs description
Illustration
LED
Unit status
Notes
Off
Unit powered
Operating mode upon initial
start-up: OFF.
The operating mode then
reverts to the one before the
energy was disconnected
Off
OFF mode, pump unit stopped
Slow flashing
AUT mode, pump unit running
The pressure is shown on the
display
Steady
AUT mode, pump unit stopped
Off
OFF mode, pump unit stopped
Slow flashing
AUT mode, pump unit running
The absorbed current of the
motor is shown on the
display
Fast flashing
OFF mode, change of the nominal Ampere value
Steady
AUT mode, pump unit stopped
Slow flashing
STOP pressure being modified
The display flashes and shows
the pressure
Steady
STOP pressure set
Slow flashing
START pressure being modified
Steady
START pressure set
Off
No alarm; pump unit running, stopped or in OFF mode
Slow flashing
Alarm triggered and automatic reset procedure in progress
Fast flashing
Start cycles alarm
Steady
Alarm triggered, pump unit locked
Alarm switched off: the pump unit can now be started, if it is
not already running
3.5 Intended use
Residential water boosting systems
Irrigation systems for gardens
Boosting systems for small commercial buildings.
Pumped liquids
Chemically and mechanically non aggressive
Non flammable and/or explosive.
With solid particles a maximum of 1.5 mm (0.06 inches) in diameter
Clean water.
Observe the operating limits in Technical Information on page 31.