en - Original instructions
12 Genyo plus, Additional Installation, Operation and Maintenance Instructions
3.4.2 LEDs description
Operating mode upon initial
start-up: OFF.
The operating mode then
reverts to the one before the
OFF mode, pump unit stopped
AUT mode, pump unit running
The pressure is shown on the
display
AUT mode, pump unit stopped
OFF mode, pump unit stopped
AUT mode, pump unit running
The absorbed current of the
motor is shown on the
display
OFF mode, change of the nominal Ampere value
AUT mode, pump unit stopped
STOP pressure being modified
The display flashes and shows
the pressure
START pressure being modified
No alarm; pump unit running, stopped or in OFF mode
Alarm triggered and automatic reset procedure in progress
Alarm triggered, pump unit locked
Alarm switched off: the pump unit can now be started, if it is
not already running
3.5 Intended use
• Residential water boosting systems
• Irrigation systems for gardens
• Boosting systems for small commercial buildings.
Pumped liquids
• Chemically and mechanically non aggressive
• Non flammable and/or explosive.
• With solid particles a maximum of 1.5 mm (0.06 inches) in diameter
• Clean water.
Observe the operating limits in Technical Information on page 31.