en - Original instructions
26 Genyo plus, Additional Installation, Operation and Maintenance Instructions
6.4 Parameters for lack of water
Ar0, disabled
•
Ar1, enabled
ART automatic restart function in case of
triggering of the A01 lack of water or
A11 minimum pressure alarm: see
The
nf0, disabled
•
nf1, enabled and
If nf1 is set, activation of the ART
function: see The ART function on page
26
Delay time till triggering of
alarm A01
•
..
Can be activated with parameter 9 set
to nf1
Example: r2.5 = 2 min and 50 s
threshold
•
..
•
P8.0 = 8 bar (psi)
•
Alarm A11 is triggered if the
pressure does not reach the set
value
•
If not set at 0.0, activation of the
ART function: see The ART function
Delay time till triggering of
alarm A11
•
..
Example: t1.5 = 1 min and 50 s
6.5 Other parameters
c10 = 10%
•
..
•
Percentage of overload of the current
absorbed by the motor for triggering
the overcurrent alarm
Loading the default parameters
rS0 = NO
6.6 The ART function
If the alarms A01 and/or A11 are triggered, an attempt is automatically made to restart the
pump unit:
• After 5 minutes
• If the alarms persist, every 30 minutes over the next 24 hours.
If the alarms continue to persist, the pump unit remains off with the LED (11) on.
Note: the alarms can be reset at any time by pressing the MENU/ENTER button (6).