en - Original instructions
Genyo plus, Additional Installation, Operation and Maintenance Instructions 19
5 Use and operation
5.1 Precautions
WARNING:
Make sure that the drained l
iquid cannot cause damage or injuries.
WARNING: Electrical hazard
Check that the unit is properly connected to the mains power supply.
WARNING:
It is prohibited to put combustible materials near the unit.
5.2 Initial start-up and basic settings
Upon initial start-up:
Set the nominal absorbed current of the motor, see Setting the current on page 20
Set the P START and P STOP pressure values, see Setting the P START and P STOP pressure
values on page 21
Open the on-off valve on the delivery line
Start the pump unit in AUT mode
Close the valve: the P STOP pressure is reached and the pump unit stops.
NOTICE:
A correctly loaded diaphra
gm pressure tank must be installed, see Hydraulic connection on
page
14.
NOTICE:
If the current is not set:
The unit remains in OFF mode
It is not possible to activate AUT mode
The overcurrent, short circuit and lack of water protection devices are deactivated.
5.2.1 OFF mode
OFF mode, pump unit stopped.
Action
Illustration
Press once to stop the pump unit