EasyManua.ls Logo

Yale Veracitor GCC060VX - Page 126

Yale Veracitor GCC060VX
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 6. (See Figure 17 Through Figure 20) (Continued)
Item No. Item
8 Hr/
1 Day
250 Hr/
6 Mo
500 Hr/
6 Mo
1000 Hr/
6 Mo
2000 Hr/
1 Yr
4000 Hr/
2 Yr
Procedure
or Quantity
Specification
20 PCV VALVE
Kubota 2.5L
X Check Only.
Replace as
Necessary.
See NOTE
15.
See Parts Manual.
OXYGEN SENSOR X Check Indicator Light
30 VALVE ADJUSTMENT
Yanmar 2.6L and 3.3L
Diesel Engines
X Adjust as
Required.
Intake
0.20 mm (0.008 in.)
Cold Exhaust
0.20 mm (0.008 in.)Cold
30 VALVE ADJUSTMENT
Kubota 2.5L (LPG)
X Adjust as
Required.
Intake and Exhaust Cold
0.18 to 22 mm (0.007 to
0.0086 in.)
30 VALVE ADJUSTMENT
Kubota 2.4L (Diesel)
X Adjust as
Required.
Intake and Exhaust Cold
0.18 to 22 mm (0.007 to
0.0086 in.)
4 DIRECT ELECTRONIC
PRESSURE REGULATOR
(DEPR)
PSI 2.4L Engine
X Check Condi-
tion.
Replace as
Necessary.
See Parts Manual.
X = Check C = Change L = Lubricate CIL = Check indicator light during operation
Maintenance Schedule
124

Table of Contents

Related product manuals