41
8. ERROR CODES
Reading Error Codes
DKN-C series units have a self-diagnostic function built into the CPU board and a separate safety device,
independent of the CPU board.
The table below shows possible causes and measures to take when safety device is triggered.
Error Codes
When an operational error or malfunction occurs, the alarm lamp on the control panel illuminates,
an error code is displayed, and an alarm sounds. When an error occurs, confirm the error code
and terminate operation immediately. Note that a temperature gauging error will be indicated by
ALARM lamp illuminating and accompanied by dashes in the display. No error code will be
displayed and no alarm will sound.
Possible causes and measures
Temperature sensor interrupted,
disconnected or other malfunction
Contact original dealer of purchase
Short circuit in SSR (solid state relay)
Contact original dealer of purchase
Heater
interruption
detected
Heater interrupted or disconnected
Current detection element interrupted,
disconnected or other malfunction
Contact original dealer of purchase
Contact original dealer of purchase
Internal
communication
error
Internal communication error,
temperature input circuit error
Contact original dealer of purchase
Overheat prevention unit activated
Overheat prevention unit interrupted
disconnected or other malfunction
Check the temperature setting.
If the unit does not reset, contact service
department.
Temperature
gauging error
Gauged temperature is out of display
range
Contact original dealer of purchase