X K 3 1 9 0-C 602
【SET 2】control parameters
Refer to table 4-4 and 4-5 according to different value of 【SET 1】 parameter 13A.
Table 4-4 Parameter 2 of Quantitative Scale
(when 0 or 1 is selected for parameter 13A in【SET 1】in table 4-3)
Param
eter
Indicator
display
Parameter explanation Remarks
1
[ ABC]
[CtrL ]
Batching control parameters
A-selection of self-correction of lead
(0: no correction, 1: correction)
B - selection of out-of-tolerance
treatment
(0: no treatment, continue operation;
1: wait for treatment until it is qualified)
C-gradual feed for material shortage
(0: no gradual feed, 1: gradual feed for
material shortage)
2
[ *****]
[Pt ]
Cycle index
Set the cycle index (0 ~ 65535, 0
means indefinite) in the full
process from feed to discharge
3
[******]
[A1 ]
Batching of material 1
4
[******]
[b1 ]
Quick feed lead of material 1
5
[******]
[C1 ]
Slow feed lead of material 1
6
[******]
[d1 ]
Material 1 allowance.
7
[******]
[A2 ]
Additive scale: batching of material 2
Subtracting scale: weight of feed
If material 2 is not needed, please
set this batching value as zero.
8
[******]
[b2 ]
Additive scale: quick feed lead of
material 2
Subtracting scale: minimum weight
of material in hopper
9
[******]
[C2 ]
Slow feed lead of material 2
This parameter is useless for
subtracting scale
10
[******]
[d2 ]
Material 2 allowance
This parameter is useless for
subtracting scale