X K 3 1 9 0-C 602
【Setting】→【Input】(date setting)→【Input】(time setting)
V. Printing
【Print】 Print the current weight(in non-operating, non-setting status).
Remark: Please confirm the type of printer before printing to avoid printing mistake.
VI.
Data Query and Removal
Method to Save Weighing Data
Set Parameter B in Parameter 9 of 【SET 1】to 1, the batching scale will
automatically save the actual result of each w
eighing. If it is set to 2, the batching scale will
automatically save every weighing time and actual weight, which cannot be accumulated
manually.
Searching Method
【Setting】→【Input】→【Input】→【Input】(search the total accumulated times)→【Input】
(search the total accumulated weight)→【Input】(search the accumulated times of Channel 1)
→【Input】(search the accumulated weight of Channel 1)→【Input】(search the accumulated times
of Channel 2)→【Input】(search the accumulated weight of Channel 2)……. Press button【↓】
or【↑】during the query. If the option at right side of the lower line shows ’1’, press button【Input】
to print the accumulated times and accumulated weights. If the option shows ‘2’, press button
【Input】to print all the weighing record.
The serial port(2)of PC can also be used to read the weighing record.
Accumulated Value Removal
Press button 【Input】 after the accumulated value is displayed and the instrument will
indicate , which means whether to remove the accumulate data. Press button【↑】→
【Input】to clear, press【Input】directly not to clear. The communication port(2)of PC can also
be used to clear the weighing record.
VII. Operation /Stop
Press the button【Operation】or 【Sop】on the keyboard, the instrument will enter running
[ AB]