X K 3 1 9 0-C 602
【SET 1】 general parameters
Table 4-3 Table for Setting of General Parameters
Param
eter
Indicator display Parameter explanation Remarks
1
[ABCDEF]
[COMM ]
Hardware selection
A-communication (1)
(0: communication (1) OFF, 1:
communication (1) ON)
B-communication (2)
(0: communication (2) OFF, 1:
communication (2) ON)
C-scoreboard
(0: scoreboard 1 OFF: scoreboard ON )
D-printer
(0: printer OFF, 1: printer ON)
E - analog quantity (0: Analog output
OFF, 1: Analog output ON)
F-display of analog quantity
(0: net weight, 1: gross weight)
Relevant parameters of zero
A-zero-setting upon startup (0: off, 1: on)
B-manual zero-setting range (0 ~ 5)
C-zero-setting range upon startup (0 ~ 5)
B, C 0 1 2 3 4 5
Max%
0 2 4 10 20 100
D-zero tracking range ( 0~8 )
D 0 1 2 3 4 5 6 7 8
2
[ ABCD]
[0 Set ]
(e) 0 0.5 1 1.5 2 2.5 3 3.5 4
AD relevant parameters
A-filtering algorithm
(0: sliding window filter 1: first-order
low-pass filter)
B-AD sampling speed (0 ~ 4)
C-AD filtering strength (0 ~ 4)
D-stable judgment (0 ~ 4)
Chara
cter
Meani
ng
0 1 2 3 4
3
[ ABCD]
[FLt ]
B
Rate
25 50 60 100 200
The larger the value of B is,
the faster the AD sampling
and the lower the stability
will be. The larger the value
of C is, the greater the
stability will be, but leading
to greater delay. The smaller
the value of D is, the stricter
the stability judgment will be,
that’s to say, it is more