X K 3 1 9 0-C 602
V. Print
【Print】 Print the current weight(under non operating, non setting status).
Remark: Please confirm the parameter setting of the printer type before printing to avoid
printing mistake.
VI.
Data Query and Removal
Method to Save Weighing Data
Set Parameter B in Parameter 9 of 【SET 1】as 1, the quantitative scale will
automatically save the actual weight of each quantitative cycle. If it is set to 2, then the
quantitative scale will automatically save the finishing time and actual weight of each quantitative
cycle. The accumulation can’t be performed manually.
Inquiry Method
Press【Setting】→【Input】→【Input】→【Input】(inquire the total accumulated times)
→【Input】(inquiry the total accumulated weight). Press button【↓】or【↑】 during the query.
If the option at right side of lower line shows ’1’, press button【Input】to print the accumulated
times and accumulated weight. If the option shows ‘2’, press button【Input】to print all weighing
records. Press button【Exit】to end printing weighing record halfway.
The communication port(2)of PC can also be used to read the weighing record.
Accumulated Value Removal
Press button 【Input】 after the accumulated value is displayed and the indicator will
indicate , which means whether to remove the accumulated data. Press button 【↑】
→【Input】to clear,and press【Input】directly not to clear.
The communication port(2)of PC can also be used to clear the weighing record.
VII. Operation /Stop
Press the button【Operation】on the indicator panel to start the cycle.
If the button【Stop】 is pressed, the indicator will enter the status of ‘pre-stop’ and the light of
‘stop’ and ‘operation’ will be ON at same time. It will be stopped after the cycle is completed. If
the button【Stop】is pressed once again under the status of ‘pre-stop’, it will enter the ‘pause’ status.
Then the indicator will stop action, all outputs will be shut down and the signal lamp ‘function’
and ‘stop’ will all be OFF. If the button 【Operation】is pressed again, the indicator will be restored
[ AB]