X K 3 1 9 0-C 602
Subtracting scale is to control the material (i.e. the material feed) weight discharged by the
control hopper. Please refer to Fig 6-2 for the function and the meaning of setting parameters
during the process and the sequence order for controlling the input and output:
Figure 6-2 Working Sequence Drawing of Subtracting Quantitative Scale
The parameter instruction in the Figure:t0:Measurement delay of material feed,t1:Quick feed over delay,
t2: Slow feed over delay(The instrument during the three periods will not judge the weight);d1:Quantitative
value of feed;q1:Quick feed lead of material 1; a1:Slow feed lead of material;o1: Allowance of material ;
b2:Min. remaining weight of material; A2:Charging weight of material
Note to working process of subtracting quantitative scale:
1. The Add Signal is needed before material feeding;
2. The Discharge Signal is needed during material discharging;
3. If the Add Signal and Discharge Signal are always valid, the indicator will automatically