X K 3 1 9 0C 602
weight of next object is captured. The main display or auxiliary display can be selected to show
the captured object weight.
Initial zero-setting is the first zero-setting operation after startup. It can be set as automatic
zero-setting upon startup (initial) or manual zero-setting. If zero-setting upon startup is
prohibited, the indicator maintains the zero point at shutdown. The initial zero-setting range can
be selected and generally ±10%Max is set. If the variation of zero point of scale exceeds the
initial zero-setting range, initial zero-setting cannot be carried out. The zero-setting range
(generally ±2%Max) is based on the zero point determined during initial zero-setting.
Main display The 6-digit 0.56 LED digital tube in upper part of display window and the
indicators on both sides are main display of C602 indicator, which is used to display major
contents such as weight and set value etc..
Auxiliary display The 6-digit 0.4 LED digital tube in lower part of display window is auxiliary
display of C602 indicator, which is used to display accumulative value, summation, date, time,
operation procedure etc.. Parameters are prompted during parameter setting and error signal is
displayed in case of error prompt.