VAN-V17001E<1>, Replacing A1000 crane with CR700
35/44
Enclosed Wall-mounted Type (UL Type 1 enclosure) Table lists the Heavy Duty (HD) rating.
Voltage
class
Capacity
(kW)
Dimensions (mm)
Drive Installation Attachment
Code No.
A1000 CR700
W H D W H D Normal installation
Three-
phase
200 V
class
0.4
140 260
147
140 300
176
(189)
100-206-987
0.75
1.1
1.5
2.2
3
164
211
(224)
3.7
5.5
167
7.5
11 180 300 187 180 340
202
(215)
100-206-988
15 220 350 197
220
400
227
Contact Yaskawa.
18.5 220 365 197 435
22 254 534
258
244 500 280
30 279 614 259 580 280
37
329 730 283 268
700
335
45 770
55
456 960 330 316 915 420
75
90 504 1168 350 444 1045 472
Three-
phase
400 V
class
0.4
140 260
147
140 300
176
(189)
100-206-987
0.75
1.1
1.5
2.2
164
211
(224)
3
3.7
5.5
167
7.5
11
180 300 180 340
202
(215)
100-206-988
15
187
18.5 220 350 197 220 400 227
Contact Yaskawa.
22 254 465 258 220 400 246
30 279 515 258 244 500 280
37
329
630 258 259 580 280
45
55
730 283 268 700 335
75
90 456 960 330
316 915 420
110
504 1168 350
132
160 444 1045 472
Note: Standard vibration tolerance specifications may not be guaranteed if an installation attachment is used.
Yaskawa recommends installing the device directly to the drive in an area with a high degree of vibration.

Other manuals for YASKAWA A1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA A1000 and is the answer not in the manual?

YASKAWA A1000 Specifications

General IconGeneral
TypeAC Drive
SeriesA1000
Input Voltage200-240V, 380-480V
Frequency Range0-400 Hz
Horsepower Range0.5 to 1000 HP
Power Range0.4 to 630 kW
Control MethodV/f Control
Overload Capacity150% for 60 seconds
BrakingDynamic Braking
CommunicationModbus
SafetySafe Torque Off (STO)
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Operating Temperature-10 to +50°C
Storage Temperature-20 to 60°C
Humidity5 to 95% RH (non-condensing)
EnclosureIP20