VAN-V17001E<1>, Replacing A1000 crane with CR700
34/44
4-3. Drive Installation Attachment to Match Mounting Dimensions
Dimensions for the open type enclosure drives and enclosed wall-mounted type drives are shown below.
CR700 has a larger depth than A1000.
The attachment makes it possible to mount CR700 using the same mounting holes as A1000.
First mount the installation attachment to the holes that A1000 was using, and then mount CR700 to the
attachment.
The installation depth increases due to the size of the attachment. The number in parenthesis indicates
the dimension when using the attachments.
OpenTypeEnclosure(IP20) Table lists the Heavy Duty (HD) rating.
Voltage
Class
Capacity
(kW)
Dimensions (mm)
Drive Installation Attachment
Code No.
A1000 CR700
W H D W H D Normal installation External heatsink
Three-
phase
200 V
class
0.4
140 260
147
140 260
176
(189䠅
100-206-987
Contact
Yaskawa.
0.75
1.1
1.5
2.2
3
164
211
(224)
3.7
5.5
167
7.5
11 180 300 187 180 300
202
(215)
100-206-988
15 220 350 197 220 350 227
Contact
Yaskawa.
18.5 220 365 197 220 350 227
22 250 400
258
240 400 280
30 275 450 255 450 280
37
325 550 283 264 543 335
45
55
450 705 330 312 700 420
75
90 500 800 350 440 800 472
Three-
phase
400 V
class
0.4
140 260
147
140 260
176
(189䠅
100-206-987
Contact
Yaskawa.
0.75
1.5
2.2
164
211
(224)
3
3.7
5.5
167
7.5
11
180 300 180 300
202
(215)
100-206-988
15 187
18.5 220 350 197 220 350 227
Contact
Yaskawa.
22 250 400
258
220 350 246
30 275 450 240 400 280
37
325 510 258 255 450 280
45
55
325 550 283 264 543 335
75
90 450 705 330
312 700 420
110
500 800 350
132
160
440 800 472
185 500 950
370
220
670 1140 510
1136 480
315