5-72
îš„ Copy Function: o3
User constants for the copy function are shown in the following table.
Con-
stant
Number
Name Description
Setting
Range
Factory
Setting
Change
during
Opera-
tion
Control Methods
MEMO
BUS
Regis-
ter
Page
V/f
V/f
with
PG
Open
Loop
Vec-
tor
Flux
Vec-
tor
o3-01
Copy func-
tion selec-
tion
0: Normal operation
1: READ (Inverter to
Operator)
2: COPY (Operator to
Inverter)
3: Verify (compare)
0 to 3 0 No A A A A 515H 6-151
o3-02
Read per-
mitted
selection
0: Read prohibited
1: Read permitted
0 or 1 0 No A A A A 516H 6-151