MANUAL NO. TOEP C710606 15E
YASKAWA AC Drive V1000
Compact Vector Control Drive
Quick Start Guide
Type: CIMR-VC
Models:
200 V Class, Three-Phase Input: 0.1 to 18.5 kW
200 V Class, Single-Phase Input: 0.1 to 4.0 kW
400 V Class, Three-Phase Input: 0.37 to 18.5 kW
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
COSMOS140×182 (英文)新CI
MANUAL NO. TOEP C710606 15E
YASKAWA AC Drive V1000
Compact Vector Control Drive
Quick Start Guide
Type: CIMR-VC
Models:
200 V Class, Three-Phase Input: 0.1 to 18.5 kW
200 V Class, Single-Phase Input: 0.1 to 4.0 kW
400 V Class, Three-Phase Input: 0.37 to 18.5 kW
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
COSMOS140×182 (英文)新CI
MANUAL NO. TOEP C710606 15E
YASKAWA AC Drive V1000
Compact Vector Control Drive
Quick Start Guide
Type: CIMR-VC
Models:
200 V Class, Three-Phase Input: 0.1 to 18.5 kW
200 V Class, Single-Phase Input: 0.1 to 4.0 kW
400 V Class, Three-Phase Input: 0.37 to 18.5 kW
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.

Questions and Answers:

YASKAWA CIMR-V 4A0023F Specifications

General IconGeneral
ModelCIMR-V 4A0023F
Output Current2.3 A
Frequency Range0-400 Hz
Control Methodvector control
Protection FeaturesOvercurrent, overvoltage, undervoltage, short circuit
Cooling MethodFan
Operating Temperature-10°C to +50°C
Humidity95% RH or less (non-condensing)
Altitude1000m or less
Vibration5.9 m/s² or less

Summary

Safety Instructions and General Warnings

General Safety Instructions and Warnings

Essential safety instructions, warnings, and precautions for handling and operating the drive.

Electrical Installation

Main and Control Circuit Wiring Overview

General overview of main and control circuit wiring diagrams and connections.

Start Up

Drive Setup Procedure and Power On

Step-by-step guide for initial drive setup, including power on and basic checks.

Control Method, Duty, and Auto-Tuning

Selection of control mode, duty rating, and the process for auto-tuning motor data.

Troubleshooting

General Faults, Alarms, and Programming Errors

Common faults, alarms, causes, corrective actions, and operator programming errors.

Specific Faults and Auto-Tuning Errors

Detailed list of specific drive faults and errors encountered during auto-tuning.