37
Drive Parameter Listing
(n005-n017)Section 8
PARA- SETTING RANGE SETTING FACTORY USER PARA.
METER NAME (AND UNITS) INCREMENT SETTING SETTING REF.
n005 Stop Method
0: Ramp to stop
10 5.24
1: Coast to stop
n006 Reverse Prohibit
0: Reverse Run enabled
10
1: Reverse Run disabled
0: STOP key is effective regardless of
programming of n003
n007 STOP Key Function
1: STOP key is effective only when sequence
10 5.13
command (per n003) is from Digital Operator
0: Frequency Reference from digital
n008
Reference Selection -
operator pot 1 0 5.13
Digital Operator
1: Frequency Reference from n024
0: ENTER key must be pressed to write-in
n009
Frequency Reference Setting new value
10 5.13
Method From Digital Operator 1: ENTER key does not have to be pressed
to write-in new value
Operation Selection 0: Disabled (operation continues)
n010 When Digital Operator is 1: Enabled (motor coasts to a stop and fault 1 0 5.15
Disconnected is displayed)
n011 Frequency - Max. 50.0 to 400.0 0.1 (Hz) 60.0
n012
Voltage - Max.
0.1 to 255.0 (230V drive)
0.1 (V)
230.0
0.2 to 510.0 (460V drive) 460.0
n013
Frequency - Max.
0.2 to 400.0 0.1 (Hz) 60.0
Voltage Point
n014 Frequency - Midpoint 0.1 to 399.9 0.1 (Hz) (Note 2) 5.27
n015
Voltage - Midpoint
0.1 to 255.0 (230V drive)
0.1 (V) (Note 2)
0.2 to 510.0 (460V drive)
n016 Frequency - Min. 0.1 to 10.0 0.1 (Hz) (Note 2)
n017
Voltage - Min.
0.1 to 50.0 (230V drive)
0.1 (V) (Note 2)
0.2 to 100.0 (460V drive)
V7 Parameters - Continued
IG.V7.01_new format.qxd 4/18/05 1:21 PM Page 37