7 Related Parameters
34 YASKAWA TOBP C730600 29A V1000 Option LCD Operator Installation Manual
o2-01
LOCAL/
REMOTE
Key Function
Selection
Enables/Disables the LCD Operator Option LOCAL/REMOTE
key.
0: Disabled
1: Enabled
1
o2-02
STOP Key
Function
Selection
Enables/Disables the operator panel STOP key when the drive is
operated form external sources (not operator).
0: Disabled
1: Enabled
1
o2-05
Frequency
Reference
Setting
Method
Selection
Selects if the ENTER key press is required when inputting the
frequency reference by the operator keypad.
0: Data/Enter key must be pressed to enter a frequency reference.
1: Data/Enter key is not required. The frequency reference is
adjusted by the up and down arrow keys.
0
o2-06
Operation
Selection
when LCD
Operator
Option
is
Disconnected
Sets drive action when the LCD Operator Option is removed in
LOCAL mode or with b1-02 = 0.
0: The drive will continue operation.
1: The drive will trigger a fault (oPr) and the motor will coast to
stop.
0
o3-01
Copy Function
Selection
This parameter controls the copying of parameters to and from
the LCD Operator Option.
0: COPY SELECT (no function)
1: All parameters are copied from the drive to the LCD Operator
Option.
2: All parameters are copied from the LCD Operator Option to
the drive.
3: Parameter settings in the drive are compared to those in the
LCD Operator Option.
Note: When using the copy function, the drive model number
(o2-04), software number (U1-14), and control method (A1-02)
must match or an error will occur.
0
o3-02
Copy
Allowable
Enables or disables reading of drive parameter settings.
0: Disabled - Read not allowed
1: Enabled - Read allowed
0
No. Name Description Default