4
Parameter Copy Mode
4.2 Operations
4-5
(2) Notes on Read-out Parameters Function
If the parameter block which has been already saved is selected, and read-out
parameter function is executed, the parameter block is overwritten.
Press the Key to cancel the operation while reading parameters. “Canceled” is
displayed and the display returns to the parameter block selection display.
When the reading operation is cancelled, or the digital operator is disconnected
from the SERVOPACK during reading operation, the selected parameter block
becomes empty block (“
∗∗∗∗
”).
During reading operation, the executing process is displayed sequentially as shown
below. The reading operation takes about 10 seconds.
When the reading operation is completed, a part of the SERVOPACK model num-
ber is registered as the name of block where the parameters are saved. The blocks
whose parameters were read out from the same SERVOPACK have the same
name.
While the parameters are being read
out from the SERVOPACK
Reading operation completed
Reading operation cancelled
00:∗∗∗∗
Reading
Parameters..
BB SERVO OP
00:∗∗∗∗
Canceled
BB SERVO OP
00:SGDV R70
Completed
BB SERVO OP

Table of Contents

Other manuals for YASKAWA E-7 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA E-7 Series and is the answer not in the manual?

YASKAWA E-7 Series Specifications

General IconGeneral
BrandYASKAWA
ModelE-7 Series
CategoryServo Drives
LanguageEnglish

Related product manuals