EasyManua.ls Logo

YASKAWA F7 - Page 184

YASKAWA F7
255 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters A - 19
F1-07
Integral Function During
Accel/Decel Selection
PG Ramp PI/I Sel
Sets integral control during acceleration/deceleration to either
enabled or disabled.
0: Disabled - The integral function is not used while accelerating
or decelerating.
1: Enabled - The integral function is used at all times.
0 to 1 0 - A - -
F1-08
Overspeed Detection Level
PG Overspd Level
Configures the overspeed fault (OS) detection.
OS fault will occur, if the motor speed feedback is greater than the
F1-08 setting for a time longer than F1-09. F1-08 is set as a
percentage of the maximum output frequency (E1-04). See F1-03.
0 to 120 115% - A - A
F1-09
Overspeed Detection Delay
Time
PG Overspd Time
0.0 to 2.0 0.0 sec - A - A
F1-10
Excessive Speed
Deviation Detection Level
PG Deviate Level
Configures the speed deviation fault (DEV) detection.
DEV fault will occur if the speed deviation is greater than the
F1-10 setting for a time longer than F1-11. F1-10 is set as a
percentage of the maximum output frequency (E1-04).
Speed deviation is the difference between actual motor speed and
the frequency reference command. See F1-04.
0 to 50 10% - A - A
F1-11
Excessive Speed
Deviation Detection Level
PG Deviate Level
0.0 to
10.0
0.5 sec - A - A
F1-12
Number of PG
Gear Teeth 1
PG # Gear Teeth1
Sets the gear ratio between the motor shaft and the encoder (PG).
A gear ratio of 1 will be used if either of these parameters is set to 0.
This function is not available in flux vector control.
0 to 1000
0-A- -
F1-13
Number of PG
Gear Teeth 2
PG # Gear Teeth2
0-A- -
F1-14
PG Open-Circuit
Detection Time
PGO Detect Time
Configures the PG open (PGO) function. PGO will be detected if no
PG pulses are detected for a time longer than F1-14. See F1-02.
0.0 to
10.0
2.0 sec - A - A
F1-21
<3021>
PG Constant 2
PG Pulse / Rev 2
Sets the number of pulses for the encoder (pulse generator) for each
full rotation of Motor 2.
0 to
60000
1024 No Q No Q
F1-22
<3021>
PG Rotation 2
PG Rotation Sel2
Determines the direction of rotation for the encoder (PG) connected
to Motor 2.
0: Phase A leads with Forward Run Command.
(Phase B leads with Reverse Run Command.)
1: Phase B leads with Forward Run Command.
(Phase A leads with Reverse Run Command.)
0, 1 0 No Q No Q
F1-23
<3021>
Number of PG
Gear Teeth 1
PG Gear Teeth1
Sets the number of gear teeth (deceleration ratio) between Motor 2
and the pulse generator.
A gear ratio of 1 will be used if either of these constants is set to 0.
0 to 1000 0 No A No No
F1-24
<3021>
Number of PG
Gear Teeth 2
PG
Gear Teeth2
0 to 1000 0 No A No No
F1-25
<3021>
Hardware Disconnect
Detection Selection CH 1
Hardware PGO ch1
Enables or disables the drive from detecting when the PG option on
CH1 has been disconnected.
0: Disabled
1: Enabled
Enabled when using PG-T2 or Z2.
0, 1 1 No A No A
F1-26
<3021>
Hardware Disconnect
Detection Selection CH 2
Hardware PGO ch2
Enables or disables the drive from detecting when the PG option on
CH2 has been disconnected.
0: Disabled
1: Enabled
Enabled when using PG-Z2.
0, 1 1 No A No A
AI-14 Setup
F2-01
AI-14 Input Selection
AI-14 Input Sel
Sets the function for channel 1 to 3 of the AI-14B analog input
reference option board.
0: 3-channel individual (Channel 1: terminal A1, Channel 2:
terminal A2, Channel 3: terminal A3)
1: 3-channel addition (Summed values of channels 1 to 3 is the
frequency reference)
When set to 0, select 1 for b1-01. In this case, the multi-function
input “Option/Inverter selection” cannot be used.
0 to 1 0 A A A A
Denotes that parameter can be changed when the Drive is running.
* Enabled when an option card is connected to the PG encoder 2CH input (F1-21 to F1-24).
Table A.1 F7 Parameter List (Continued)
Parameter
No.
Parameter Name
Digital Operator Display
Description
Setting
Range
Factory
Setting
Control Method
V/F
V/F
w/PG
Open
Loop
Vector
Flux
Vector
Input pulses from PG (PPR) x 60
F1-01
F1-13
F1-12
x
Input pulses from PG (PPR) x 60
PG Constant (F1-21)
F1-24
F1-23
x
http://www.aotewell.com
Aotewell
Email: Sales@aotewell.com
Tel: +(86) 755 8660 6182
Aotewell
http://www.aotewell.com

Table of Contents

Other manuals for YASKAWA F7

Related product manuals