Loading...
Electrical Installation 2 - 29
4037
FS5972-100-35
or
FS5972-130-35
B
100A
or
130A
9.92 (4.5)
or
10.36 (4.7)
3.54 x 12.83 x 5.9
(90 x 326 x 150)
or
3.54 x 14.375 x 7
(90 x 366 x 180)
4045
4055 FS5972-130-35 B 130A
10.36
(4.7)
3.54 x 14.375 x 7
(90 x 366 x 180)
4075 FS5972-170-40 B 170A
13.23
(6)
4.75 x 17.75 x 6.6675
(120 x 451 x 170)
4090
FS5972-250-37
or
FS3359-250-28
A 250A
24.25 (11)
or
15.43 (7)
5.125 x 24 x 9.475
(130 x 610 x 240)
or
9.05 x 11.80 x 4.92
(230 x 300 x 125)
4110
4132
FS5972-400-99
or
FS3359-400-99
A 400A
23.15 (10.5)
or
40.78 (18.5)
10.24 x 15.20 x 4.53
(260 x 386 x 115)
or
11.81 x 24.01 x 6.30
(300 x 610 x 160)
4160
4185 FS5972-410-99 A 410A 23.15 (10.5)
10.24 x 15.20 x 4.53
(260 x 386 x 115)
4220 FS5972-600-99 A 600A
24.25
(11)
10.24 x 15.20 x 5.31
(260 x 386 x 135)
4300 FS5972-800-99 A 800A
68.34
(31)
11.81 x 28.19 x 6.30
(300 x 716 x 160)
* Maximum Voltage: 480Vac 3-phase
Ambient Temperature: 45 Degrees Celsius (maximum)
Maximum motor cable length: 50m Class B, 50m Class A
Permissible emission of power drive systems for commercial and light environment (EN61800-3, A11) (General availability, 1st environment)
Table 2.16 Recommended EMC Filters (Continued)
Drive Model
CIMR-F7U
EMC Filter
Model Number
EN
55011
Class*
Current
Rating
Weight
lb.
(kg)
Dimensions
inches
(mm)