2.5 Drive Models and Drive Watt Loss
YASKAWA SIEPC71061753C GA500 Technical Manual 37
Three-Phase 200 V Class
Table 2.5 Drive Watt Loss (HD, Fc = 2 kHz)
Model
The rated output
current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
2001 0.8 2 6 4 10
2002 1.6 2 7 7 14
2004 3.0 2 9 13 22
2006 5.0 2 13 22 35
2008 6.9 2 14 30 44
2010 8.0 2 17 37 54
2012 11.0 2 23 49 72
2018 14.0 2 26 61 87
2021 17.6 2 36 83 119
2030 25.0 2 45 163 208
2042 33.0 2 55 200 255
2056 47.0 2 77 269 346
2070 60.0 2 108 411 519
2082
*1
75.0 2 132 439 571
*1 There is not a finless-type 2082 model.
Table 2.6 Drive Watt Loss (HD, Fc = Default Setting)
Model
The rated output
current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
2001 0.8 10 6 5 11
2002 1.6 10 7 8 15
2004 3.0 10 10 16 26
2006 5.0 10 14 27 41
2008 6.9 8 15 35 50
2010 8.0 8 18 43 61
2012 11.0 8 24 56 80
2018 14.0 8 30 82 112
2021 17.6 8 40 108 148
2030 25.0 8 49 187 236
2042 33.0 8 60 232 292
2056 47.0 8 85 318 403
2070 60.0 8 119 473 592
2082
*1
75.0 8 148 525 673
*1 There is not a finless-type 2082 model.
Table 2.7 Drive Watt Loss (ND)
Model
The rated output
current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
2001 1.2 2 7 5 12
2002 1.9 2 9 9 18
2004 3.5 2 11 16 27
2006 6 2 14 25 39
2008 8 2 18 37 55
2010 9.6 2 25 51 76
2012 12.2 2 30 61 91

Table of Contents