EasyManuals Logo

YASKAWA J1000 User Manual

YASKAWA J1000
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
7 Troubleshooting
TOEP C710606 27 J1000 Quick Start Guide 27
ENGLISH
Operator Programing Errors
An Operator Programming Error (OPE) occurs when an inapplicable parameter is set or an
individual parameter setting is inappropriate. This monitor will display the parameter that is
causing the OPE error.
LED Operator
Display
Cause Corrective Action
oPE01
Drive capacity and value set to o2-04 do not
match.
Correct the value set to o2-04.
oPE02
Parameters were set outside the allowable setting
range.
Set parameters to the proper values.
oPE03
A contradictory setting is assigned to multi-func-
tion contact inputs H1-01 through to H1-05.
The same function is assigned to two inputs
(this excludes “External fault” and “Not used”)
Input functions which require the setting of
other input functions were set alone.
Input functions that are not allowed to be used
simultaneously have been set.
Fix any incorrect settings.
Refer to the instruction manual for more details.
oPE05
No option unit is installed and one of the follow-
ing is true:
b1-01=2 or 3
b1-02=2
Install the required option unit.
Correct the values set to b1-01 and b1-02.
oPE10
The V/f pattern setting is incorrect.
Check the V/f pattern settings.
Refer to the instruction manual for more details.

Other manuals for YASKAWA J1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA J1000 and is the answer not in the manual?

YASKAWA J1000 Specifications

General IconGeneral
SeriesJ1000
Voltage Class200V, 400V
Frequency50/60 Hz
Enclosure RatingIP20
Enclosure TypeOpen type
Voltage200-240V, 380-480V
Control MethodV/f control
Overload Capacity150% for 60 seconds
ProtectionOvercurrent, Overvoltage, Undervoltage, Overheat, Ground Fault, Short Circuit
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Humidity5-95% (non-condensing)
EnclosureIP20
Input Voltage200-240V, 380-480V

Related product manuals